Search Results (3159 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-48919 1 Cursor 1 Cursor 2026-04-15 N/A
Cursor is a code editor built for programming with AI. Prior to Sep 27, 2024, if a user generated a terminal command via Cursor's Terminal Cmd-K/Ctrl-K feature and if the user explicitly imported a malicious web page into the Terminal Cmd-K prompt, an attacker with control over the referenced web page could have a significant chance of influencing a language model to output arbitrary commands for execution in the user's terminal. This scenario would require the user explicitly opt-in to including the contents of a compromised webpage, and it would require that the attacker display prompt injection text in the the contents of the compromised webpage. A server-side patch to not stream back newlines or control characters was released on September 27, 2024, within two hours of the issue being reported. Additionally, Cursor 0.42 includes client-side mitigations to prevent any newline or control character from being streamed into the terminal directly. It also contains a new setting, `"cursor.terminal.usePreviewBox"`, which, if set to true, streams the response into a preview box whose contents then have to be manually accepted before being inserted into the terminal. This setting is useful if you're working in a shell environment where commands can be executed without pressing enter or any control character. The patch has been applied server-side, so no additional action is needed, even on older versions of Cursor. Separately, Cursor's maintainers also recommend, as best practice, to only include trusted pieces of context in prompts.
CVE-2024-49397 1 Elvaco 1 Cme3100 Firmware 2026-04-15 N/A
The affected product is vulnerable to a cross-site scripting attack which may allow an attacker to bypass authentication and takeover admin accounts.
CVE-2024-49775 2026-04-15 9.8 Critical
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.
CVE-2024-4995 2026-04-15 9.8 Critical
Wapro ERP Desktop is vulnerable to MS SQL protocol downgrade request from a server side, what could lead to an unencrypted communication vulnerable to data interception and modification. This issue affects Wapro ERP Desktop versions before 9.00.0.
CVE-2024-4996 2026-04-15 9.8 Critical
Use of a hard-coded password for a database administrator account created during Wapro ERP installation allows an attacker to retrieve embedded sensitive data stored in the database. The password is same among all Wapro ERP installations. This issue affects Wapro ERP Desktop versions before 8.90.0.
CVE-2024-4999 2026-04-15 N/A
A vulnerability in the web-based management interface of multiple Ligowave devices could allow an authenticated remote attacker to execute arbitrary commands with elevated privileges.This issue affects UNITY: through 6.95-2; PRO: through 6.95-1.Rt3883; MIMO: through 6.95-1.Rt2880; APC Propeller: through 2-5.95-4.Rt3352.
CVE-2024-5023 1 Netflix 1 Consoleme 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Netflix ConsoleMe allows Command Injection.This issue affects ConsoleMe: before 1.4.0.
CVE-2024-47138 1 Myscada 2 Mypro Manager, Mypro Runtime 2026-04-15 9.8 Critical
The administrative interface listens by default on all interfaces on a TCP port and does not require authentication when being accessed.
CVE-2024-47407 1 Myscada 2 Mypro Manager, Mypro Runtime 2026-04-15 10 Critical
A parameter within a command does not properly validate input within myPRO Manager which could be exploited by an unauthenticated remote attacker to inject arbitrary operating system commands.
CVE-2024-45367 1 Optigo 1 Ons-s8 Firmware 2026-04-15 9.1 Critical
The web server for ONS-S8 - Spectra Aggregation Switch includes an incomplete authentication process, which can lead to an attacker authenticating without a password.
CVE-2024-45369 1 Myscada 2 Mypro Manager, Mypro Runtime 2026-04-15 8.1 High
The web application uses a weak authentication mechanism to verify that a request is coming from an authenticated and authorized resource.
CVE-2024-4332 1 Fortra 1 Tripwire Enterprise 2026-04-15 N/A
An authentication bypass vulnerability has been identified in the REST and SOAP API components of Tripwire Enterprise (TE) 9.1.0 when TE is configured to use LDAP/Active Directory SAML authentication and its optional "Auto-synchronize LDAP Users, Roles, and Groups" feature is enabled. This vulnerability allows unauthenticated attackers to bypass authentication if a valid username is known. Exploitation of this vulnerability could allow remote attackers to gain privileged access to the APIs and lead to unauthorized information disclosure or modification.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).