Export limit exceeded: 380705 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 380705 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 380705 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 380705 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (2319 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-40827 1 Siemens 2 Software Center, Solid Edge Se2025 2026-04-15 7.8 High
A vulnerability has been identified in Siemens Software Center (All versions < V3.5), Solid Edge SE2025 (All versions < V225.0 Update 10). The affected application is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system.
CVE-2024-41170 1 Siemens 1 Tecnomatix Plant Simulation 2026-04-15 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0015), Tecnomatix Plant Simulation V2404 (All versions < V2404.0004). The affected applications contain a stack based overflow vulnerability while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-35292 1 Siemens 10 Simatic S7-200 Smart Cpu Cr40, Simatic S7-200 Smart Cpu Cr60, Simatic S7-200 Smart Cpu Sr20 and 7 more 2026-04-15 8.2 High
A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices are using a predictable IP ID sequence number. This leaves the system susceptible to a family of attacks which rely on the use of predictable IP ID sequence numbers as their base method of attack and eventually could allow an attacker to create a denial of service condition.
CVE-2025-40753 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2024-31978 1 Siemens 1 Sinec-nms 2026-04-15 7.6 High
A vulnerability has been identified in SINEC NMS (All versions < V2.0 SP2). Affected devices allow authenticated users to export monitoring data. The corresponding API endpoint is susceptible to path traversal and could allow an authenticated attacker to download files from the file system. Under certain circumstances the downloaded files are deleted from the file system.
CVE-2024-41981 1 Siemens 1 Simcenter Nastran 2026-04-15 7.8 High
A vulnerability has been identified in Simcenter Femap V2306 (All versions), Simcenter Femap V2401 (All versions), Simcenter Femap V2406 (All versions). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted BDF files. This could allow an attacker to execute code in the context of the current process.
CVE-2025-40834 2 Mendix, Siemens 2 Mendix, Mendix 2026-04-15 5.7 Medium
A vulnerability has been identified in Mendix RichText (All versions >= V4.0.0 < V4.6.1). Affected widget does not properly neutralize the input. This could allow an attacker to execute cross-site scripting attacks.
CVE-2024-31484 1 Siemens 2 Cpc80 Central Processing\/communication, Cpci85 Central Processing\/communication 2026-04-15 7.8 High
A vulnerability has been identified in CPC80 Central Processing/Communication (All versions < V16.41), CPCI85 Central Processing/Communication (All versions < V5.30), CPCX26 Central Processing/Communication (All versions < V06.02), ETA4 Ethernet Interface IEC60870-5-104 (All versions < V10.46), ETA5 Ethernet Int. 1x100TX IEC61850 Ed.2 (All versions < V03.27), PCCX26 Ax 1703 PE, Contr, Communication Element (All versions < V06.05). The affected devices contain an improper null termination vulnerability while parsing a specific HTTP header. This could allow an attacker to execute code in the context of the current process or lead to denial of service condition.
CVE-2024-35303 1 Siemens 1 Tecnomatix Plant Simulation 2026-04-15 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0012), Tecnomatix Plant Simulation V2404 (All versions < V2404.0001). The affected applications contain a type confusion vulnerability while parsing specially crafted MODEL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22958)
CVE-2024-31485 1 Siemens 2 Cpci85 Firmware, Sicore Base System 2026-04-15 7.2 High
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.30), SICORE Base system (All versions < V1.3.0). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
CVE-2024-39675 1 Siemens 24 Ruggedcom Ros Rmc30, Ruggedcom Ros Rmc30nc, Ruggedcom Ros Rp110 and 21 more 2026-04-15 8.8 High
A vulnerability has been identified in RUGGEDCOM RMC30 (All versions < V4.3.10), RUGGEDCOM RMC30NC (All versions < V4.3.10), RUGGEDCOM RP110 (All versions < V4.3.10), RUGGEDCOM RP110NC (All versions < V4.3.10), RUGGEDCOM RS400 (All versions < V4.3.10), RUGGEDCOM RS400NC (All versions < V4.3.10), RUGGEDCOM RS401 (All versions < V4.3.10), RUGGEDCOM RS401NC (All versions < V4.3.10), RUGGEDCOM RS416 (All versions < V4.3.10), RUGGEDCOM RS416NC (All versions < V4.3.10), RUGGEDCOM RS416NCv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416P (All versions < V4.3.10), RUGGEDCOM RS416PNC (All versions < V4.3.10), RUGGEDCOM RS416PNCv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416v2 V5.X (All versions < V5.9.0), RUGGEDCOM RS910 (All versions < V4.3.10), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910LNC (All versions), RUGGEDCOM RS910NC (All versions < V4.3.10), RUGGEDCOM RS910W (All versions < V4.3.10), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920LNC (All versions), RUGGEDCOM RS920W (All versions). In some configurations the affected products wrongly enable the Modbus service in non-managed VLANS. Only serial devices are affected by this vulnerability.
CVE-2024-32008 1 Siemens 1 Spectrum Power 4 2026-04-15 7.8 High
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to a local privilege escalation due to an exposed debug interface on the localhost. This allows any local user to gain code execution as administrative application user.
CVE-2023-32735 1 Siemens 11 Simatic Step 7, Simatic Step 7 Safety, Simatic Wincc and 8 more 2026-04-15 6.5 Medium
A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
CVE-2024-32009 1 Siemens 1 Spectrum Power 4 2026-04-15 7.8 High
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to a local privilege escalation due to wrongly set permissions to a binary which allows any local attacker to gain administrative privileges.
CVE-2024-37997 1 Siemens 2 Jt Open, Plm Xml Sdk 2026-04-15 7.8 High
A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
CVE-2025-40801 1 Siemens 8 Comos, Nx, Simcenter 3d and 5 more 2026-04-15 8.1 High
A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), JT Bi-Directional Translator for STEP (All versions), NX V2412 (All versions < V2412.8900 with Cloud Entitlement (bundled as NX X)), NX V2506 (All versions < V2506.6000 with Cloud Entitlement (bundled as NX X)), Simcenter 3D (All versions < V2506.6000 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Femap (All versions < V2506.0002 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Studio (All versions < V2506.0001), Simcenter System Architect (All versions < V2506.0001), Tecnomatix Plant Simulation (All versions < V2504.0007). The SALT SDK is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
CVE-2024-33498 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 5.3 Medium
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected applications do not properly release memory that is allocated when handling specifically crafted incoming packets. This could allow an unauthenticated remote attacker to cause a denial of service condition by crashing the service when it runs out of memory. The service is restarted automatically after a short time.
CVE-2024-32014 1 Siemens 1 Spectrum Power 4 2026-04-15 4.7 Medium
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to alter the local database which contains the application credentials. This allows an attacker to gain administrative application privileges.
CVE-2024-33494 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 6.5 Medium
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected components do not properly authenticate heartbeat messages. This could allow an unauthenticated remote attacker to affected the availability of secondary RTLS systems configured using a TeeRevProxy service and potentially cause loss of data generated during the time the attack is ongoing.
CVE-2024-52335 1 Siemens 1 Syngo Plaza Vb30e 2026-04-15 9.8 Critical
A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF05). The affected application do not properly sanitize input data before sending it to the SQL server. This could allow an attacker with access to the application could use this vulnerability to execute malicious SQL commands to compromise the whole database.