| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| CWE-798 Use of Hard-coded Credentials |
| A vulnerability in the .sdd file allows an attacker to read default passwords stored in plain text within the code. By exploiting these plaintext credentials, an attacker can log into affected SICK products as an “Authorized Client” if the customer has not changed the default password. |
| A vulnerability was discovered in the storage policy for certain sets of encryption keys in the HPE Telco Network Function Virtual Orchestrator. Successful Exploitation could lead to unauthorized parties gaining access to sensitive system information. |
| Hardcoded credentials in gsigel14 ATLAS-EPIC commit f29312c (2025-05-26). |
| Hard-coded login credentials were found in HPE Networking Instant On Access Points, allowing anyone with knowledge of it to bypass normal device authentication. Successful exploitation could allow a remote attacker to gain administrative access to the system. |
| A vulnerability has been found in TOZED ZLT M30S and ZLT M30S PRO 1.47/3.09.06. Affected is an unknown function of the component Web Interface. Such manipulation leads to hard-coded credentials. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Use of Hard-coded Credentials vulnerability in Baicells Snap Router BaiCE_BMI on EP3011 (User Passwords modules) allows unauthorized access to the device. |
| A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.
Other related CVE's are CVE-2025-14095 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required Configuration for Exposure:
Attacker requires physical access to the analyzer.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication. |
| All the Toshiba printers contain a shell script using the same hardcoded key to encrypt logs. An attacker can decrypt the encrypted files using the hardcoded key. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| An issue in H3C Device R365V300R004 allows a remote attacker to execute arbitrary code via the default password. NOTE: the Supplier's position is that their "product lines enforce or clearly prompt users to change any initial credentials upon first use. At most, this would be a case of misconfiguration if an administrator deliberately ignored the prompts, which is outside the scope of CVE definitions." |
| This vulnerability exists in ZKTeco WL20 due to hard-coded private key stored in plaintext within the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and analyzing the binary data to retrieve private key stored in the firmware of the targeted device.
Successful exploitation of this vulnerability could allow the attacker to perform unauthorized decryption of sensitive data and Man-in-the-Middle (MitM) attacks on the targeted device. |
| The application uses several hard-coded credentials to encrypt config files during backup, to decrypt the new firmware during an update and some passwords allow a direct connection to the database server of the affected device. |
| The Versa Director uses PostgreSQL (Postgres) to store operational and configuration data. It is also needed for High Availability function of the Versa Director. The default configuration has a common password across all instances of Versa Director. By default, Versa Director configures Postgres to listen on all network interfaces. This combination allows an unauthenticated attacker to access and administer the database or read local filesystem contents to escalate privileges on the system.
Exploitation Status:
Versa Networks is not aware of this exploitation in any production systems. A proof of concept exists in the lab environment.
Workarounds or Mitigation:
Starting with the latest 22.1.4 version of Versa Director, the software will automatically restrict access to the Postgres and HA ports to only the local and peer Versa Directors. For older releases, Versa recommends performing manual hardening of HA ports. Please refer to the following link for the steps https://docs.versa-networks.com/Solutions/System_Hardening/Perform_Manual_Hardening_for_Versa_Director#Secure_HA_Ports
This vulnerability is not exploitable on Versa Directors if published Firewall guidelines are implemented. We have validated that no Versa-hosted head ends have been affected by this vulnerability. All Versa-hosted head ends are patched and hardened.
Please contact Versa Technical Support or Versa account team for any further assistance.
Software Download Links:
22.1.4: https://support.versa-networks.com/support/solutions/articles/23000026708-release-22-1-4 |
| Vulnerabilities* in ActADUR local server product, developed and maintained by ProTNS, allows Remote Code Inclusion on host systems.
* vulnerabilities:
*
Improper Neutralization of Special Elements used in a Command ('Command Injection')
* Use of Hard-coded Credentials
* Improper Authentication
* Binding to an Unrestricted IP Address
The vulnerability has been rated as critical.This issue affects ActADUR: from v2.0.1.9 before v2.0.2.0., hence updating to version v2.0.2.0. or above is required. |
| The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP >= 6.4.1. |
| In KDE libksieve before 23.03.80, kmanagesieve/session.cpp places a cleartext password in server logs because a username variable is accidentally given a password value. |
| It appears that some hardcoded keys are used for authentication to internal API. Knowing these private keys may allow attackers to bypass authentication and reach administrative interfaces. As for the affected products/models/versions, see the reference URL. |
| API keys for some cloud services are hardcoded in the "main" binary. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| A vulnerability was found in shsuishang ShopSuite ModulithShop up to 45a99398cec3b7ad7ff9383694f0b53339f2d35a. Affected by this issue is some unknown functionality of the component RSA/OAuth2/Database. The manipulation results in hard-coded credentials. The attack can be executed remotely. The exploit has been made public and could be used. This product implements a rolling release for ongoing delivery, which means version information for affected or updated releases is unavailable. |
| An attacker with local access to the medical office computer can
access restricted functions of the Elefant Service tool by using a
hard-coded "Hotline" password in the Elefant service binary, which is shipped with the software. |