| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability was found in H3C GR-1800AX up to 100R008 and classified as critical. Affected by this issue is the function EnableIpv6 of the file /goform/aspForm. The manipulation of the argument param leads to buffer overflow. Access to the local network is required for this attack to succeed. The exploit has been disclosed to the public and may be used. |
| A vulnerability was identified in H3C Magic B3 up to 100R002. This affects the function AddMacList/EditMacList of the file /goform/aspForm. The manipulation of the argument param leads to buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability has been found in H3C GR-5400AX up to 100R008 and classified as critical. This vulnerability affects the function Edit_List_SSID of the file /goform/aspForm. The manipulation of the argument param leads to buffer overflow. The attack needs to be approached within the local network. |
| In FDL1, there is a possible missing payload size check. This could lead to memory buffer overflow without requiring additional execution privileges. |
| In BootRom, there's a possible missing payload size check. This could lead to memory buffer overflow without requiring additional execution privileges. |
| On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| ESPAsyncWebServer is an asynchronous HTTP and WebSocket server library for ESP32, ESP8266, RP2040 and RP2350. In versions up to and including 3.7.8, a CRLF (Carriage Return Line Feed) injection vulnerability exists in the construction and output of HTTP headers within `AsyncWebHeader.cpp`. Unsanitized input allows attackers to inject CR (`\r`) or LF (`\n`) characters into header names or values, leading to arbitrary header or response manipulation. Manipulation of HTTP headers and responses can enable a wide range of attacks, making the severity of this vulnerability high. A fix is available at pull request 211 and is expected to be part of version 3.7.9. |
| A vulnerability in the ipsecmgr process of Cisco ASR 5000 Series Software (StarOS) could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition.
This vulnerability is due to insufficient validation of incoming Internet Key Exchange Version 2 (IKEv2) packets. An attacker could exploit this vulnerability by sending specifically malformed IKEv2 packets to an affected device. A successful exploit could allow the attacker to cause the ipsecmgr process to restart, which would disrupt ongoing IKE negotiations and result in a temporary DoS condition.Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability. |
| The vulnerability was found in OpenShift Service Mesh 2.6.3 and 2.5.6. This issue occurs due to improper sanitization of HTTP headers by Envoy, particularly the x-forwarded-for header. This lack of sanitization can allow attackers to inject malicious payloads into service mesh logs, leading to log injection and spoofing attacks. Such injections can mislead logging mechanisms, enabling attackers to manipulate log entries or execute reflected cross-site scripting (XSS) attacks. |
| arduino-esp32 provides an Arduino core for the ESP32. Versions prior to 3.3.0-RC1 and 3.2.1 contain a HTTP Response Splitting vulnerability. The `sendHeader` function takes arbitrary input for the HTTP header name and value, concatenates them into an HTTP header line, and appends this to the outgoing HTTP response headers. There is no validation or sanitization of the `name` or `value` parameters before they are included in the HTTP response. If an attacker can control the input to `sendHeader` (either directly or indirectly), they could inject carriage return (`\r`) or line feed (`\n`) characters into either the header name or value. This could allow the attacker to inject additional headers, manipulate the structure of the HTTP response, potentially inject an entire new HTTP response (HTTP Response Splitting), and/or ause header confusion or other HTTP protocol attacks. Versions 3.3.0-RC1 and 3.2.1 contain a fix for the issue. |
| A security vulnerability has been detected in jarun nnn up to 5.1. The impacted element is the function show_content_in_floating_window/run_cmd_as_plugin of the file nnn/src/nnn.c. The manipulation leads to double free. An attack has to be approached locally. The identifier of the patch is 2f07ccdf21e705377862e5f9dfa31e1694979ac7. It is suggested to install a patch to address this issue. |
| A vulnerability was found in Novastar CX40 up to 2.44.0. It has been rated as critical. This issue affects the function getopt of the file /usr/nova/bin/netconfig of the component NetFilter Utility. The manipulation of the argument cmd/netmask/pipeout/nettask leads to stack-based buffer overflow. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability, which was classified as critical, has been found in TA-Lib up to 0.6.4. This issue affects the function setInputBuffer of the file src/tools/ta_regtest/ta_test_func/test_minmax.c of the component ta_regtest. The manipulation leads to out-of-bounds write. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The identifier of the patch is 5879180e9070ec35d52948f2f57519713256a0f1. It is recommended to apply a patch to fix this issue. |
| Improper buffer restrictions in some Intel(R) System Security Report and System Resources Defense firmware may allow a privileged user to potentially enable escalation of privilege via local access. |
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. |
| A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1. |
| The JTAG interface of Wattsense Bridge devices can be accessed with physical access to the PCB. After connecting to the interface, full access to the device is possible. This enables an attacker to extract information, modify and debug the device's firmware. All known versions are affected. |
| In Nessus versions prior to 10.8.4, a non-authenticated attacker could alter Nessus logging entries by manipulating http requests to the application. |
| A vulnerability was found in PX4-Autopilot 1.12.3. It has been classified as problematic. This affects the function MavlinkReceiver::handle_message_trajectory_representation_waypoints of the file mavlink_receiver.cpp of the component TRAJECTORY_REPRESENTATION_WAYPOINTS Message Handler. The manipulation leads to stack-based buffer overflow. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. |