| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The UMA product with software V200R001 and V300R001 has an information leak vulnerability. An attacker could exploit them to obtain some sensitive information, causing information leak. |
| The Windows kernel component on Microsoft Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, Windows RT 8.1, Windows 10 Gold, 1511, 1607, and 1703, and Windows Server 2016 allows an information disclosure vulnerability when it improperly handles objects in memory, aka "Win32k Information Disclosure Vulnerability". This CVE ID is unique from CVE-2017-8678, CVE-2017-8680, CVE-2017-8677, and CVE-2017-8681. |
| Microsoft Outlook 2007 SP3, Outlook 2010 SP2, Outlook 2013 SP1, Outlook 2013 RT SP1, and Outlook 2016 as packaged in Microsoft Office allows an information disclosure vulnerability due to the way that it discloses the contents of its memory, aka "Microsoft Office Outlook Information Disclosure Vulnerability". |
| In Cloud Foundry Foundation CAPI-release versions after v1.6.0 and prior to v1.38.0 and cf-release versions after v244 and prior to v270, there is an incomplete fix for CVE-2017-8035. If you took steps to remediate CVE-2017-8035 you should also upgrade to fix this CVE. A carefully crafted CAPI request from a Space Developer can allow them to gain access to files on the Cloud Controller VM for that installation, aka an Information Leak / Disclosure. |
| Windows kernel in Microsoft Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, Windows RT 8.1, Windows 10 Gold, 1511, 1607, and 1703, and Windows Server 2016 allows an information disclosure vulnerability when it fails to properly initialize a memory address, aka "Windows Kernel Information Disclosure Vulnerability". |
| Samsung Android devices with L(5.0/5.1), M(6.0), and N(7.x) software allow attackers to obtain sensitive information by reading a world-readable log file after an unexpected reboot. The Samsung ID is SVE-2017-8290. |
| FFmpeg before 2.8.12, 3.0.x and 3.1.x before 3.1.9, 3.2.x before 3.2.6, and 3.3.x before 3.3.2 does not properly restrict HTTP Live Streaming filename extensions and demuxer names, which allows attackers to read arbitrary files via crafted playlist data. |
| NetApp Clustered Data ONTAP before 8.3.2P11, 9.0 before P4, and 9.1 before P5 allow attackers to obtain sensitive password information by leveraging logging of passwords entered non-interactively on the command line. |
| In Mosquitto through 1.4.12, mosquitto.db (aka the persistence file) is world readable, which allows local users to obtain sensitive MQTT topic information. |
| A Password in Configuration File issue was discovered in Hikvision DS-2CD2xx2F-I Series V5.2.0 build 140721 to V5.4.0 build 160530, DS-2CD2xx0F-I Series V5.2.0 build 140721 to V5.4.0 Build 160401, DS-2CD2xx2FWD Series V5.3.1 build 150410 to V5.4.4 Build 161125, DS-2CD4x2xFWD Series V5.2.0 build 140721 to V5.4.0 Build 160414, DS-2CD4xx5 Series V5.2.0 build 140721 to V5.4.0 Build 160421, DS-2DFx Series V5.2.0 build 140805 to V5.4.5 Build 160928, and DS-2CD63xx Series V5.0.9 build 140305 to V5.3.5 Build 160106 devices. The password in configuration file vulnerability could allow a malicious user to escalate privileges or assume the identity of another user and access sensitive information. |
| Microsoft browsers on when Microsoft Windows 7 SP1, Windows Server 2008 R2 SP1, Windows 8.1, Windows RT 8.1, and Windows Server 2012 and R2, Windows 10 Gold, 1511, 1607, and 1703, and Windows Server 2016 allow a security feature bypass vulnerability when they improperly handle redirect requests, aka "Microsoft Browser Security Feature Bypass". |
| An issue was discovered in SMA Solar Technology products. When signed into Sunny Explorer with a wrong password, it is possible to create a debug report, disclosing information regarding the application and allowing the attacker to create and save a .txt file with contents to his liking. An attacker may use this for information disclosure, or to write a file to normally unavailable locations on the local system. NOTE: the vendor reports that "the information contained in the debug report is of marginal significance." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| An issue was discovered in SMA Solar Technology products. By sending crafted packets to an inverter and observing the response, active and inactive user accounts can be determined. This aids in further attacks (such as a brute force attack) as one now knows exactly which users exist and which do not. NOTE: the vendor's position is that this "is not a security gap per se." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| The Windows kernel component on Microsoft Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, and Windows RT 8.1 allows an information disclosure vulnerability when it improperly handles objects in memory, aka "Win32k Information Disclosure Vulnerability". This CVE ID is unique from CVE-2017-8678, CVE-2017-8677, CVE-2017-8681, and CVE-2017-8687. |
| Graphics in Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, Windows RT 8.1, Windows 10 Gold, 1511, 1607, 1703, Windows Server 2016, Microsoft Office 2007 Service Pack 3, and Microsoft Office 2010 Service Pack 2 allows improper disclosure of memory contents, aka "Graphics Uniscribe Information Disclosure Vulnerability". This CVE ID is unique from CVE-2017-0286, CVE-2017-0287, CVE-2017-0288, CVE-2017-0289, CVE-2017-8532, and CVE-2017-8533. |
| An information disclosure vulnerability in the BlackBerry Workspaces Server could result in an attacker gaining access to source code for server-side applications by crafting a request for specific files. |
| The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421733-160420a-CMCST) and DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST) devices allows remote attackers to discover a CM MAC address by sniffing Wi-Fi traffic and performing simple arithmetic calculations. |
| The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST) devices allows remote attackers to compute password-of-the-day values via unspecified vectors. |
| A vulnerability in the ConfD server of the Cisco Elastic Services Controller (ESC) could allow an authenticated, remote attacker to acquire sensitive system information. The vulnerability is due to insufficient protection of sensitive files on the system. An attacker could exploit this vulnerability by logging into the ConfD server and executing certain commands. An exploit could allow an unprivileged user to view configuration parameters that can be maliciously used. Cisco Bug IDs: CSCvd76409. Known Affected Releases: 2.3, 2.3(2). |
| A vulnerability in the Elastic Services Controller (ESC) web interface of the Cisco Ultra Services Platform could allow an authenticated, remote attacker to acquire sensitive information. The vulnerability is due to the transmission of sensitive information as part of a GET request. An attacker could exploit this vulnerability by sending a GET request to a vulnerable device. An exploit could allow the attacker to view information regarding the Ultra Services Platform deployment. Cisco Bug IDs: CSCvd76406. Known Affected Releases: 21.0.v0.65839. |