Search Results (113 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-5632 2026-04-15 N/A
Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, create a WiFi network with a default password. A user is neither advised to change it during the installation process, nor such a need is described in the manual. As the cameras from the same kit connect automatically, it is very probable for the default password to be left unchanged.
CVE-2024-54015 2026-04-15 7.5 High
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials.
CVE-2025-10542 1 Imonitor 1 Imonitor Eam 2026-04-15 9.8 Critical
iMonitor EAM 9.6394 ships with default administrative credentials that are also displayed within the management client’s connection dialog. If the administrator does not change these defaults, a remote attacker can authenticate to the EAM server and gain full control over monitored agents and data. This enables reading highly sensitive telemetry (including keylogger output) and issuing arbitrary actions to all connected clients.
CVE-2020-36915 2026-04-15 7.5 High
Adtec Digital SignEdje Digital Signage Player v2.08.28 contains multiple hardcoded default credentials that allow unauthenticated remote access to web, telnet, and SSH interfaces. Attackers can exploit these credentials to gain root-level access and execute system commands across multiple Adtec Digital product versions.
CVE-2024-10476 2026-04-15 8 High
Default credentials are used in the above listed BD Diagnostic Solutions products. If exploited, threat actors may be able to access, modify or delete data, including sensitive information such as protected health information (PHI) and personally identifiable information (PII). Exploitation of this vulnerability may allow an attacker to shut down or otherwise impact the availability of the system. Note: BD Synapsys™ Informatics Solution is only in scope of this vulnerability when installed on a NUC server. BD Synapsys™ Informatics Solution installed on a customer-provided virtual machine or on the BD Kiestra™ SCU hardware is not in scope.
CVE-2024-12013 2026-04-15 7.6 High
A CWE-1392 “Use of Default Credentials” was discovered affecting the 130.8005 TCP/IP Gateway running firmware version 12h. The device exposes an FTP server with default and easy-to-guess admin credentials. A remote attacker capable of interacting with the FTP server could gain access and perform changes over resources exposed by the service such as configuration files where password hashes are saved or where network settings are stored.
CVE-2024-1300 1 Redhat 20 A Mq Clients, Amq Broker, Amq Streams and 17 more 2026-04-15 5.4 Medium
A vulnerability in the Eclipse Vert.x toolkit causes a memory leak in TCP servers configured with TLS and SNI support. When processing an unknown SNI server name assigned the default certificate instead of a mapped certificate, the SSL context is erroneously cached in the server name map, leading to memory exhaustion. This flaw allows attackers to send TLS client hello messages with fake server names, triggering a JVM out-of-memory error.
CVE-2024-28093 1 Adtran 1 Netvanta 3120 Firmware 2026-04-15 8.8 High
The TELNET service of AdTran NetVanta 3120 18.01.01.00.E devices is enabled by default, and has default credentials for a root-level account.
CVE-2024-31069 2026-04-15 7.4 High
IO-1020 Micro ELD web server uses a default password for authentication.
CVE-2024-6245 2026-04-15 7.4 High
Use of Default Credentials vulnerability in Maruti Suzuki SmartPlay on Linux (Infotainment Hub modules) allows attacker to try common or default usernames and passwords.The issue was detected on a 2022 Maruti Suzuki Brezza in India Market. This issue affects SmartPlay: 66T0.05.50.
CVE-2025-5124 2026-04-15 8.1 High
A vulnerability classified as critical has been found in Sony SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N and SNC-RX570N up to 1.30. This affects an unknown part of the component Administrative Interface. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. It is recommended to change the configuration settings. The vendor was contacted early about this issue. They confirmed the existence but pointed out that they "have published the 'Hardening Guide' on the Web from July 2018 to January 2025 and have thoroughly informed customers of the recommendation to change their initial passwords".
CVE-2025-54756 1 Brightsign 2 Brightsign Os Series 4 Players, Brightsign Os Series 5 Players 2026-04-15 8.4 High
BrightSign players running BrightSign OS series 4 prior to v8.5.53.1 or series 5 prior to v9.0.166 use a default password that is guessable with knowledge of the device information. The latest release fixes this issue for new installations; users of old installations are encouraged to change all default passwords.
CVE-2025-55051 2026-04-15 10 Critical
CWE-1392: Use of Default Credentials
CVE-2025-6951 1 Safecam 1 X300 2026-04-15 4.3 Medium
A vulnerability classified as problematic was found in SAFECAM X300 up to 20250611. This vulnerability affects unknown code of the component FTP Service. The manipulation leads to use of default credentials. Access to the local network is required for this attack to succeed. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-7740 1 Hitachienergy 1 Supros 2026-04-15 N/A
Default credentials vulnerability exists in SuprOS product. If exploited, this could allow an authenticated local attacker to use an admin account created during product deployment.
CVE-2021-47707 1 Commax 1 Cvd-axx Dvr 2026-04-15 N/A
COMMAX CVD-Axx DVR 5.1.4 contains weak default administrative credentials that allow remote password attacks and disclose RTSP stream. Attackers can exploit this by sending a POST request with the 'passkey' parameter set to '1234', allowing them to access the web control panel.
CVE-2022-50803 2026-04-15 9.8 Critical
JM-DATA ONU JF511-TV version 1.0.67 uses default credentials that allow attackers to gain unauthorized access to the device with administrative privileges.
CVE-2024-12286 2026-04-15 9.8 Critical
MOBATIME Network Master Clock - DTS 4801 allows attackers to use SSH to gain initial access using default credentials.
CVE-2024-12902 2026-04-15 8.4 High
ANCHOR from Global Wisdom Software is an integrated product running on a Windows virtual machine. The underlying Windows OS of the product contains high-privilege service accounts. If these accounts use default passwords, attackers could remotely log in to the virtual machine using the default credentials.
CVE-2024-13893 2026-04-15 N/A
Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, might share same credentials for telnet service. Hash of the password can be retrieved through physical access to SPI connected memory. For the telnet service to be enabled, the inserted SD card needs to have a folder with a specific name created.  Two products were tested, but since the vendor has not replied to reports, patching status remains unknown, as well as groups of devices and firmware ranges in which the same password is shared. Newer firmware versions might be vulnerable as well.