| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| WebEOC before 6.0.2 uses a weak encryption scheme for passwords, which makes it easier for attackers to crack passwords. |
| Microsoft SQL Server 6.0 through 2000, with SQL Authentication enabled, uses weak password encryption (XOR), which allows remote attackers to sniff and decrypt the password. |
| Videsh Sanchar Nigam Limited (VSNL) Integrated Dialer Software 1.2.000, when the "Save Password" option is used, stores the password with a weak encryption scheme (one-to-one mapping) in a registry key, which allows local users to obtain and decrypt the password. |
| Sharp Zaurus PDA SL-5000D and SL-5500 uses a salt of "A0" to encrypt the screen-locking password as stored in the Security.conf file, which makes it easier for local users to guess the password via brute force methods. |
| Click2Learn Ingenium Learning Management System 5.1 and 6.1 uses weak encryption for passwords (reversible algorithm), which allows attackers to obtain passwords. |
| HCL DRYiCE Optibot Reset Station is impacted by insecure encryption of One-Time Passwords (OTPs). This could allow an attacker with access to the database to recover some or all encrypted values. |
| Inadequate Encryption Strength vulnerability allow an authenticated attacker to execute arbitrary OS Commands via encrypted package upload.This issue affects Envoy: 4.x and 5.x |
| HCL DRYiCE Optibot Reset Station is impacted by insecure encryption of security questions. This could allow an attacker with access to the database to recover some or all encrypted values. |
| A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain a weak encryption mechanism based on a hard-coded key.
This could allow an attacker to guess or decrypt the password from the cyphertext. |
| An issue was discovered in Kaseya Rapid Fire Tools Network Detective through 2.0.16.0. A vulnerability exists in the EncryptionUtil class because symmetric encryption is implemented in a deterministic and non-randomized fashion. The method Encrypt(byte[] clearData) derives both the encryption key and the IV from a fixed, hardcoded input by using a static salt value. As a result, identical plaintext inputs always produce identical ciphertext outputs. This is true for both FIPS and non-FIPS generated passwords. In other words, there is a cryptographic implementation flaw in the password encryption mechanism. Although there are multiple encryption methods grouped under FIPS and non-FIPS classifications, the logic consistently results in predictable and reversible encrypted outputs due to the lack of per-operation randomness and encryption authentication. |
| This vulnerability exists in USB Pratirodh due to the usage of a weaker cryptographic algorithm (hash) SHA1 in user login component. A local attacker with administrative privileges could exploit this vulnerability to obtain the password of USB Pratirodh on the targeted system.
Successful exploitation of this vulnerability could allow the attacker to take control of the application and modify the access control of registered users or devices on the targeted system.
|
| HCL DRYiCE Optibot Reset Station is impacted by a missing Strict Transport Security Header. This could allow an attacker to intercept or manipulate data during redirection. |
| Inadequate encryption strength issue exists in SS1 Ver.16.0.0.10 and earlier (Media version:16.0.0a and earlier). If this vulnerability is exploited, a function that requires authentication may be accessed by a remote unauthenticated attacker. |
| Nokia SR OS bof.cfg file encryption is vulnerable to a brute force attack. This weakness allows an attacker in possession of the encrypted file to decrypt the bof.cfg file and obtain the BOF configuration content. |
| Weak encryption vulnerability in Hitachi JP1/IT Desktop Management 2 - Smart Device Manager on Windows.This issue affects JP1/IT Desktop Management 2 - Smart Device Manager: from 12-00 before 12-00-08, from 11-10 through 11-10-08, from 11-00 through 11-00-05, from 10-50 through 10-50-06. |
| The use of a weak cryptographic key pair in the signature verification process in WPS Office (Kingsoft) on Windows allows an attacker who successfully recovered the private key to sign components.
As older versions of WPS Office did not validate the update server's certificate, an Adversary-In-The-Middle attack was possible allowing updates to be hijacked. |
| A vulnerability exists in Algo Edge up to 2.1.1 - a previously used (legacy) component of navify® Algorithm Suite. The vulnerability impacts the authentication mechanism of this component and could allow an attacker with adjacent access to the laboratory network and the Algo Edge system to craft valid authentication tokens and access the component. Other components of navify® Algorithm Suite are not affected. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.64), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.64), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.64), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.64), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.65), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.65), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.65), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.65), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.65), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.65), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.65), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.65), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.65), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.65), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.65), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.65), SIPROTEC 5 7SX85 (CP300) (All versions < V9.65), SIPROTEC 5 7UM85 (CP300) (All versions < V9.64), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.65), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.65), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.65), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.65), SIPROTEC 5 7VE85 (CP300) (All versions < V9.64), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.65), SIPROTEC 5 7VU85 (CP300) (All versions < V9.64), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.62), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.64). The affected devices are supporting weak ciphers on several ports (443/tcp for web, 4443/tcp for DIGSI 5 and configurable port for syslog over TLS).
This could allow an unauthorized attacker in a man-in-the-middle position to decrypt any data passed over to and from those ports. |
| Programs/P73_SimplePythonEncryption.py illustrates a simple Python encryption example using the RSA Algorithm. In versions prior to commit 6ce60b1, an attacker may be able to decrypt the data using brute force attacks and because of this the whole application can be impacted. This issue has been patched in commit 6ce60b1. A workaround involves increasing the key size, for RSA or DSA this is at least 2048 bits, for ECC this is at least 256 bits. |
| Weak server key used for TLS encryption. The following products are affected: Acronis Cyber Protect 16 (Linux, macOS, Windows) before build 39938. |