| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| dectalk-tts is a Node package to interact with the aeiou Dectalk web API. In `dectalk-tts@1.0.0`, network requests to the third-party API are sent over HTTP, which is unencrypted. Unencrypted traffic can be easily intercepted and modified by attackers. Anyone who uses the package could be the victim of a man-in-the-middle (MITM) attack. The network request was upgraded to HTTPS in version `1.0.1`. There are no workarounds, but some precautions include not sending any sensitive information and carefully verifying the API response before saving it. |
| The decrypted configuration file contains the password in cleartext
which is used to configure WINSelect. It can be used to remove the
existing restrictions and disable WINSelect entirely. |
| Sensitive customer information is stored in the device without encryption. |
| NewPass before 1.2.0 stores passwords (rather than password hashes) directly, which makes it easier to obtain unauthorized access to sensitive information. NOTE: in each case, data at rest is encrypted, but is decrypted within process memory during use. |
| The lack of encryption in the DuoxMe (formerly Blue) application binary in versions prior to 3.3.1 for iOS devices allows an attacker to gain unauthorised access to the application code and discover sensitive information. |
| Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GT Designer3 Version1 (GOT2000) all versions and Mitsubishi Electric GT Designer3 Version1 (GOT1000) all versions allows a local unauthenticated attacker to obtain plaintext credentials from the project file for GT Designer3. This could allow the attacker to operate illegally GOT2000 series or GOT1000 series by using the obtained credentials. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected systems transmit client-side resources without proper cryptographic protection. This could allow an attacker to eavesdrop on and modify resources in transit. A successful exploit requires an attacker to be in the network path between the RTLS Locating Manager server and a client (MitM). |
| Toshiba printers will display the password of the admin user in clear-text and additional passwords when sending 2 specific HTTP requests to the internal API. An attacker stealing the cookie of an admin or abusing a XSS vulnerability can recover this password in clear-text and compromise the printer. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| A vulnerability in the IPS Manager, Central Manager, and Local Manager communication workflow allows an attacker to control the destination of a request by manipulating the parameter, thereby leveraging sensitive information. |
| With physical access to the device and enough time an attacker can desolder the flash memory, modify it and then reinstall it because of missing encryption. Thus, essential files, such as "/etc/passwd", as well as stored certificates, cryptographic keys, stored PINs and so on can be modified and read, in order to gain SSH root access on the Linux-based K7 model. On the Windows CE based K5 model, the password for the Access Manager can additionally be read in plain text from the stored SQLite database. |
| All WorkExaminer Professional traffic between monitoring client, console and server is transmitted as plain text. This allows an attacker with access to the network to read the transmitted sensitive data. An attacker can also freely modify the data on the wire. The monitoring clients transmit their data to the server using the unencrypted FTP. Clients connect to the FTP server on port 12304 and transmit the data unencrypted. In addition, all traffic between the console client and the server at port 12306 is unencrypted. |
| CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test
credentials in the firmware binary |
| A vulnerability classified as problematic was found in Netis WF-2404 1.1.124EN. Affected by this vulnerability is an unknown functionality of the component BusyBox Shell. The manipulation leads to cleartext storage of sensitive information. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| The Temporal api-go library prior to version 1.44.1 did not send `update response` information to Data Converter when the proxy package within the api-go module was used in a gRPC proxy prior to transmission. This resulted in information contained within the `update response` field not having Data Converter transformations (e.g. encryption) applied. This is an issue only when using the UpdateWorkflowExecution APIs (released on 13th January 2025) with a proxy leveraging the api-go library before version 1.44.1.
Other data fields were correctly sent to Data Converter. This issue does not impact the Data Converter server. Data was encrypted in transit. Temporal Cloud services are not impacted. |
| A flaw was found in Event-Driven Automation (EDA) in Ansible Automation Platform (AAP), which lacks encryption of sensitive information. An attacker with network access could exploit this vulnerability by sniffing the plaintext data transmitted between the EDA and AAP. An attacker with system access could exploit this vulnerability by reading the plaintext data stored in EDA and AAP databases. |
| Missing encryption of sensitive data in Korenix JetPort 5601v3 allows Eavesdropping.This issue affects JetPort 5601v3: through 1.2. |
| Sensitive data could be exposed to non- privileged users in a configuration file. Local access to the computer with a low- privileged account is required to access the configuration file containing the sensitive data. |
| When using domain users as BRAIN2 users, communication with Active Directory services is unencrypted. This can lead to the interception of authentication data and compromise confidentiality. |
| SummaryThis advisory addresses a security vulnerability in Mautic where sensitive .env configuration files may be directly accessible via a web browser. This exposure could lead to the disclosure of sensitive information, including database credentials, API keys, and other critical system configurations.
Sensitive Information Disclosure via .env File Exposure: The .env file, which typically contains environment variables and sensitive application configurations, is directly accessible via a web browser due to missing web server configurations that restrict access to such files. This allows an unauthenticated attacker to view the contents of this file by simply navigating to its URL.
MitigationUpdate Mautic to the latest Mautic version.
By default, Mautic does not use .env files for production data.
For Apache users: Ensure your web server is configured to respect .htaccess files.
For Nginx users: As Nginx does not inherently support .htaccess files, you must manually add a configuration block to your Nginx server configuration to deny access to .env files. Add the following to your Nginx configuration for the Mautic site:
location ~ /\.env {
deny all;
}