Search Results (412 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-8767 1 Acronis 3 Backup Extension For Plesk, Backup Plugin For Cpanel \& Whm, Backup Plugin For Directadmin 2026-04-15 N/A
Sensitive data disclosure and manipulation due to unnecessary privileges assignment. The following products are affected: Acronis Backup plugin for cPanel & WHM (Linux) before build 619, Acronis Backup extension for Plesk (Linux) before build 555, Acronis Backup plugin for DirectAdmin (Linux) before build 147.
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-8903 2026-04-15 N/A
Local active protection service settings manipulation due to unnecessary privileges assignment. The following products are affected: Acronis Cyber Protect Cloud Agent (Windows, macOS) before build 38565.
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2025-13911 2 Inductiveautomation, Microsoft 2 Ignition, Windows 2026-04-15 6.4 Medium
The vulnerability affects Ignition SCADA applications where Python scripting is utilized for automation purposes. The vulnerability arises from the absence of proper security controls that restrict which Python libraries can be imported and executed within the scripting environment. The core issue lies in the Ignition service account having system permissions beyond what an Ignition privileged user requires. When an authenticated administrator uploads a malicious project file containing Python scripts with bind shell capabilities, the application executes these scripts with the same privileges as the Ignition Gateway process, which typically runs with SYSTEM-level permissions on Windows. Alternative code execution patterns could lead to similar results.
CVE-2024-22017 2 Nodejs, Redhat 2 Nodejs, Enterprise Linux 2026-04-15 7.3 High
setuid() does not affect libuv's internal io_uring operations if initialized before the call to setuid(). This allows the process to perform privileged operations despite presumably having dropped such privileges through a call to setuid(). This vulnerability affects all users using version greater or equal than Node.js 18.18.0, Node.js 20.4.0 and Node.js 21.
CVE-2022-38691 1 Unisoc 4 Sc9863a, T310, T610 and 1 more 2026-04-15 7.8 High
In BootROM, there is a possible missing validation for Certificate Type 0. This could lead to local escalation of privilege with no additional execution privileges needed.
CVE-2024-28139 2026-04-15 8.8 High
The www-data user can elevate its privileges because sudo is configured to allow the execution of the mount command as root without a password. Therefore, the privileges can be escalated to the root user. The risk has been accepted by the vendor and won't be fixed in the near future.
CVE-2024-28140 2026-04-15 6.1 Medium
The scanner device boots into a kiosk mode by default and opens the Scan2Net interface in a browser window. This browser is run with the permissions of the root user. There are also several other applications running as root user. This can be confirmed by running "ps aux" as the root user and observing the output.
CVE-2024-11075 1 Sick Ag 1 Incoming Goods Suite 2026-04-15 8.8 High
A vulnerability in the Incoming Goods Suite allows a user with unprivileged access to the underlying system (e.g. local or via SSH) a privilege escalation to the administrative level due to the usage of component vendor Docker images running with root permissions. Exploiting this misconfiguration leads to the fact that an attacker can gain administrative control. over the whole system.
CVE-2025-3364 1 Hgiga 1 Powerstation 2026-04-15 6.7 Medium
The SSH service of PowerStation from HGiga has a Chroot Escape vulnerability, allowing attackers with root privileges to bypass chroot restrictions and access the entire file system.
CVE-2025-6949 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems.
CVE-2025-9055 3 Axis, Axis Communications Ab, Linux 3 Axis Os, Axis Os, Linux 2026-04-15 6.4 Medium
The VAPIX Edge storage API that allowed a privilege escalation, enabling a VAPIX administrator-privileged user to gain Linux Root privileges. This flaw can only be exploited after authenticating with an administrator-privileged service account.
CVE-2022-38695 2026-04-15 7.8 High
In BootRom, there's a possible unchecked command index. This could lead to local escalation of privilege with no additional execution privileges needed.
CVE-2022-38694 2026-04-15 7.8 High
In BootRom, there is a possible unchecked write address. This could lead to local escalation of privilege with no additional execution privileges needed.
CVE-2026-4498 1 Elastic 1 Kibana 2026-04-14 7.7 High
Execution with Unnecessary Privileges (CWE-250) in Kibana’s Fleet plugin debug route handlers can lead reading index data beyond their direct Elasticsearch RBAC scope via Privilege Abuse (CAPEC-122). This requires an authenticated Kibana user with Fleet sub-feature privileges (such as agents, agent policies, and settings management).
CVE-2026-1346 1 Ibm 4 Security Verify Access, Security Verify Access Container, Verify Identity Access and 1 more 2026-04-10 9.3 Critical
IBM Verify Identity Access Container 11.0 through 11.0.2 and IBM Security Verify Access Container 10.0 through 10.0.9.1 and IBM Verify Identity Access 11.0 through 11.0.2 and IBM Security Verify Access 10.0 through 10.0.9.1 could allow a locally authenticated user to escalate their privileges to root due to execution with unnecessary privileges than required.
CVE-2024-23299 1 Apple 1 Macos 2026-04-02 8.6 High
The issue was addressed with improved checks. This issue is fixed in macOS Monterey 12.7.4, macOS Sonoma 14.4, macOS Ventura 13.6.5. An app may be able to break out of its sandbox.