| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| VMware vCenter Server 5.5, 6.0, 6.5 allows vSphere users with certain, limited vSphere privileges to use the VIX API to access Guest Operating Systems without the need to authenticate. |
| A potential security vulnerability has been identified in HPE Application Performance Management (BSM) Platform versions 9.26, 9.30, 9.40. The vulnerability could be remotely exploited to allow code execution. |
| An issue was discovered in Veritas NetBackup 8.0 and earlier and NetBackup Appliance 3.0 and earlier. Unauthenticated CORBA interfaces permit inappropriate access. |
| Aodh as packaged in Openstack Ocata and Newton before change-ID I8fd11a7f9fe3c0ea5f9843a89686ac06713b7851 and before Pike-rc1 does not verify that trust IDs belong to the user when creating alarm action with the scheme trust+http, which allows remote authenticated users with knowledge of trust IDs where Aodh is the trustee to obtain a Keystone token and perform unspecified authenticated actions by adding an alarm action with the scheme trust+http, and providing a trust id where Aodh is the trustee. |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 21/tcp to access or alter historical measurement data stored on the device. |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp. |
| In Odoo 8.0, Odoo Community Edition 9.0 and 10.0, and Odoo Enterprise Edition 9.0 and 10.0, remote attackers can bypass authentication under certain circumstances because parameters containing 0x00 characters are truncated before reaching the database layer. This occurs because Psycopg 2.x before 2.6.3 is used. |
| Sony PCS-XG100, PCS-XG100S, PCS-XG100C, PCS-XG77, PCS-XG77S, PCS-XG77C devices with firmware versions prior to Ver.1.51 and PCS-XC1 devices with firmware version prior to Ver.1.22 allow an attacker on the same network segment to bypass authentication to perform administrative operations via unspecified vectors. |
| IBM InfoSphere Master Data Management - Collaborative Edition 11.5 could allow an unauthorized user to download reports without authentication. IBM X-Force ID: 129892. |
| firewalld.py in firewalld before 0.4.3.3 allows local users to bypass authentication and modify firewall configurations via the (1) addPassthrough, (2) removePassthrough, (3) addEntry, (4) removeEntry, or (5) setEntries D-Bus API method. |
| Summer Baby Zoom Wifi Monitor & Internet Viewing System allows remote attackers to bypass authentication, related to the MySnapCam web service. |
| Trustwave Secure Web Gateway (SWG) through 11.8.0.27 allows remote attackers to append an arbitrary public key to the device's SSH Authorized Keys data, and consequently obtain remote root access, via the publicKey parameter to the /sendKey URI. |
| With X-Pack installed, Kibana versions 5.0.0 and 5.0.1 were not properly authenticating requests to advanced settings and the short URL service, any authenticated user could make requests to those services regardless of their own permissions. |
| Remote enabling and disabling admin interface in Gemalto's HASP SRM, Sentinel HASP and Sentinel LDK products prior to Sentinel LDK RTE version 7.55 leads to new attack vectors. |
| A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server. |
| IBM Security Identity Manager Adapters 6.0 and 7.0 does not perform an authentication check for a critical resource or functionality allowing anonymous users access to protected areas. IBM X-Force ID: 128621. |
| An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database, which would allow an authenticated user to modify drug libraries, add and delete users, and change user permissions. According to Smiths-Medical, physical access to the pump is required to install drug library updates. |
| Incorrect access control in AMAG Symmetry Door Edge Network Controllers (EN-1DBC Boot App 23611 03.60 and STD App 23603 03.60; EN-2DBC Boot App 24451 01.00 and STD App 2461 01.00) enables remote attackers to execute door controller commands (e.g., lock, unlock, add ID card value) by sending unauthenticated requests to the affected devices via Serial over TCP/IP, as demonstrated by a Ud command. |
| The admin terminal in Hawt.io does not require authentication, which allows remote attackers to execute arbitrary commands via the k parameter. |
| Exploitation of Authentication vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote unauthenticated users / remote attackers to bypass ATD detection via loose enforcement of authentication and authorization. |